Description
All Myron L/controllers feature a highly refined and precise Temperature Compensation Circuit. This feature perfectly matches the NERNST equation correcting the displayed reading to 25°C. The TC may be disabled to conform with USP requirements. Built-in electronic calibration allows for fast quality checks without standard solutions. For maximum system accuracy, buffers are recommended. A push-to-test button makes set point checks easy, while the internal alarm set discourages unauthorized adjustments. Standard on all controller models is a heavy-duty 10 amp output relay, operating on either increasing or decreasing reading. Bright green/red LEDs indicate above or below-set point readings. All 720 Series II models feature an IP65/NEMA 4X water-resistant and corrosion-proof rated enclosure. Compact in size at 6″ x 4.8″, they are suitable for panel, bench, or surface mounting.
Features
– Choice of 3-1/2″ digit display or analog meter
– Advanced “Isolated” Circuitry
– Automatic temperature compensation to 25°C– Isolated 0-10 VDC Recorder Output standard– IP65/NEMA 4x water-resistant and corrosion-proof enclosure– Built-in electronic calibration– Single set point/alarm– Adjustable set point hysteresis– Solid state 24 VDC output– 10 amp relay operates on the choice of increasing or decreasing reading– Push-to-test setpoint discourages unauthorized adjustment– Selectable 115/230 VAC– Unique easily installed sensor
– Heavy Duty “F” model sensors may be installed in any direction including inverted
Applications– Reverse Osmosis – Process Control– Seawater Desalination – Waste Treatment– Food Processing – Plating– Power Plants – Laboratories– Printing – Aquaculture– Agriculture – Environmental Studies– Medical – Bleach Manufacturing
– Cooling Towers – Reduction of Chromate Waste
Specifications
– Range: 0-14 pH
– Display: Analog Models: 2.5″
Digital Models: .5″ 3-1/2 Digit LCD
Optional: 3-1/2 Digit Backlit
– Linearity: +/- 0.05% (+/- 0.01 pH units/+/- 1mV of full scale)
– Resolution: Analog Meter: +/- 0.13 pH units/+/-40mV
Digital Display: +/-0.01 pH units/+/- 1mV
– Sensitivity: 0.05% of full scale (0.01 pH/+/- 1mV)
– Stability: 0.05% of full scale (0.01 pH/+/- 1mV)
– Repeatability: 0.05% of full scale (0.01 pH/+/- 1mV)
– Calibration Check: Built-in (7 and 0 pH/0 and -2000 mV)
– Recorder Output: Isolated 0-10 VDC @ 5 mA Max
– Sensor Input: 1 (3 input options are available)
– Power: 115/230 VAC, 50/60 Hz
– Maximum Power Consumption: @115V: 100 milliamps
– Dimensions: 6″ H x 4.8″ W x 3.8″ D
– Ambient Temp Range: 32-140°F
– Weight: 2 lbs